MEGA 6/8/10/12 kW single-phase hybrid inverter — inverter fault

Beve 25 error code

The inverter's AC relay self-check failed.

Likely causes

  • AC relay welded or stuck
  • AC input voltage or frequency abnormal during the self-check
  • Internal relay drive circuit fault
  • Backfeed or wiring error on the AC input

Checks to run, in order

  1. 1Power-cycle the unit and observe whether the self-check passes
  2. 2Measure AC input voltage and frequency at the inverter terminals
  3. 3Check the AC input wiring for backfeed or a shared neutral error

Fixes

  • Restart after correcting any AC input abnormality
  • Return the unit to the repair centre if the relay check keeps failing

When to escalate

A repeated relay check failure is an internal relay fault and needs distributor service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Beve 25 mean?

The inverter's AC relay self-check failed.

How do I fix Beve 25?

Restart after correcting any AC input abnormality Return the unit to the repair centre if the relay check keeps failing

When should I escalate Beve 25?

A repeated relay check failure is an internal relay fault and needs distributor service.

Can I reset Beve 25 myself?

Only after isolating the AC and DC sides and running the checks above. If Beve 25 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Beve 25?

Beve 25 is documented for MEGA 6/8/10/12 kW single-phase hybrid inverter — inverter fault. Confirm the code on your own unit's display or manual before ordering parts.

More Beve error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting