MEGA 6/8/10/12 kW single-phase hybrid inverter — inverter fault

Beve 55 error code

Excessive DC voltage component in the AC output; the manual's troubleshooting table also describes this as output voltage unbalanced.

Likely causes

  • Output stage fault injecting a DC offset
  • Abnormal or unbalanced connected load
  • Output voltage regulation fault

Checks to run, in order

  1. 1Measure the AC output with a true-RMS meter and check for a DC offset
  2. 2Reduce the connected load and observe the output voltage (manual)
  3. 3Restart the unit and re-measure at no load

Fixes

  • Reduce the connected load
  • Restart the unit
  • If the error happens again, return the unit to the repair centre (manual)

When to escalate

If a DC offset is measured at no load, stop using the output and send the unit to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Beve 55 mean?

Excessive DC voltage component in the AC output; the manual's troubleshooting table also describes this as output voltage unbalanced.

How do I fix Beve 55?

Reduce the connected load Restart the unit If the error happens again, return the unit to the repair centre (manual)

When should I escalate Beve 55?

If a DC offset is measured at no load, stop using the output and send the unit to the distributor.

Can I reset Beve 55 myself?

Only after isolating the AC and DC sides and running the checks above. If Beve 55 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Beve 55?

Beve 55 is documented for MEGA 6/8/10/12 kW single-phase hybrid inverter — inverter fault. Confirm the code on your own unit's display or manual before ordering parts.