Lithium battery BMS

Felicity 04 error code

Low cell voltage / over-discharge protection.

Likely causes

  • Bank discharged below protection threshold
  • Cell imbalance
  • Charger not delivering expected current

Checks to run, in order

  1. 1Check state of charge and cell voltages in the BMS app
  2. 2Confirm charge source is working
  3. 3Review load profile

Fixes

  • Charge the bank fully and allow cell balancing
  • Reduce overnight load
  • Raise low-voltage cutoff where appropriate

When to escalate

Repeated over-discharge or a cell that will not balance needs a warranty assessment.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 04 mean?

Low cell voltage / over-discharge protection.

How do I fix Felicity 04?

Charge the bank fully and allow cell balancing Reduce overnight load Raise low-voltage cutoff where appropriate

When should I escalate Felicity 04?

Repeated over-discharge or a cell that will not balance needs a warranty assessment.

More Felicity error codes

Search the full error-code database in the troubleshooting tool.

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.