IVGM5-8K LP2G1 hybrid inverters (warning code list, flashing fault LED)

Felicity 22 error code

Battery under-voltage alarm or battery SOC low alarm: battery voltage is too low, or the BMS reports SOC too low, and the battery should be charged.

Likely causes

  • Battery discharged after a long outage
  • PV or grid charging unavailable
  • Low-voltage cutoff set too low
  • BMS SOC drift or a weak pack

Checks to run, in order

  1. 1Read the battery voltage and SOC on the display or app
  2. 2Confirm the PV and grid charge sources are available
  3. 3Compare the cutoff setting with the battery datasheet
  4. 4Check whether the pack recovers when charging

Fixes

  • Recharge the battery from PV or grid
  • Disconnect non-essential loads until it recovers
  • Correct the low-voltage cutoff if it is below the battery datasheet

When to escalate

If the battery will not accept charge, or the alarm returns immediately after a full charge, escalate for battery testing.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 22 mean?

Battery under-voltage alarm or battery SOC low alarm: battery voltage is too low, or the BMS reports SOC too low, and the battery should be charged.

How do I fix Felicity 22?

Recharge the battery from PV or grid Disconnect non-essential loads until it recovers Correct the low-voltage cutoff if it is below the battery datasheet

When should I escalate Felicity 22?

If the battery will not accept charge, or the alarm returns immediately after a full charge, escalate for battery testing.

Can I reset Felicity 22 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 22 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 22?

Felicity 22 is documented for IVGM5-8K LP2G1 hybrid inverters (warning code list, flashing fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.