IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 31 error code

LLC over-current fault of hardware: the hardware protection on the LLC converter stage tripped.

Likely causes

  • Internal LLC converter fault on the DC link
  • Load or PV surge feeding through the converter
  • Damaged power component or gate drive
  • Sustained operation at the power limit

Checks to run, in order

  1. 1Restart the inverter 2-3 times as the manual directs
  2. 2Check the connected load and PV input for a recent surge or lightning event
  3. 3Confirm the battery voltage is within the inverter's range
  4. 4Inspect the unit for a burning smell or visible damage before retrying

Fixes

  • Reduce the load and restart
  • If the code returns with a normal load, remove the unit from service
  • Book service - the LLC stage is not installer-serviceable

When to escalate

A repeated code 31 is an internal converter fault - escalate to the distributor with the serial number and fault history.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 31 mean?

LLC over-current fault of hardware: the hardware protection on the LLC converter stage tripped.

How do I fix Felicity 31?

Reduce the load and restart If the code returns with a normal load, remove the unit from service Book service - the LLC stage is not installer-serviceable

When should I escalate Felicity 31?

A repeated code 31 is an internal converter fault - escalate to the distributor with the serial number and fault history.

Can I reset Felicity 31 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 31 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 31?

Felicity 31 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.