IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 37 error code

LLC soft-start failure: the LLC converter did not reach its working point during soft start.

Likely causes

  • Internal LLC converter component fault
  • Control-board or gate-drive fault
  • A short on the DC link holding the converter down
  • Repeated restart attempts into the same fault

Checks to run, in order

  1. 1Restart the inverter 2-3 times and note whether the code returns immediately
  2. 2Check the battery and PV voltages are within range
  3. 3Disconnect the load and try one clean start
  4. 4Inspect for visible damage or a burning smell

Fixes

  • Restart once with the load disconnected
  • If the soft start still fails, remove the unit from service
  • Book service - do not keep cycling the inverter

When to escalate

Code 37 that returns on every start is an internal converter fault - escalate to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 37 mean?

LLC soft-start failure: the LLC converter did not reach its working point during soft start.

How do I fix Felicity 37?

Restart once with the load disconnected If the soft start still fails, remove the unit from service Book service - do not keep cycling the inverter

When should I escalate Felicity 37?

Code 37 that returns on every start is an internal converter fault - escalate to the distributor.

Can I reset Felicity 37 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 37 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 37?

Felicity 37 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.