IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 41 error code

BUS over-voltage fault: the internal DC bus voltage exceeded its protection ceiling.

Likely causes

  • PV or AC surge feeding the DC bus
  • Internal voltage-regulation fault
  • Battery voltage above the inverter's range
  • Lightning damage to the input stage

Checks to run, in order

  1. 1Measure the PV and battery voltages against the inverter specification
  2. 2Restart 2-3 times and note whether the code returns under load
  3. 3Check for signs of a lightning strike or surge on the PV and AC side
  4. 4Confirm the battery bank voltage matches the inverter model

Fixes

  • Correct any over-voltage source and restart
  • If the bus trips again with normal input voltages, remove the unit from service
  • Book service for the power stage

When to escalate

A repeated code 41 with normal PV and battery voltages is an internal bus fault - escalate to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 41 mean?

BUS over-voltage fault: the internal DC bus voltage exceeded its protection ceiling.

How do I fix Felicity 41?

Correct any over-voltage source and restart If the bus trips again with normal input voltages, remove the unit from service Book service for the power stage

When should I escalate Felicity 41?

A repeated code 41 with normal PV and battery voltages is an internal bus fault - escalate to the distributor.

Can I reset Felicity 41 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 41 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 41?

Felicity 41 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting