IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 49 error code

INV over-current of software: the inverter output current exceeded the software protection limit.

Likely causes

  • Load above the inverter's rated output
  • High inrush from a motor or compressor
  • Short or faulty appliance on the backup circuit
  • Output current limit set too low for the load

Checks to run, in order

  1. 1Clamp the output current and compare it with the inverter rating
  2. 2Switch off loads one at a time to identify the culprit
  3. 3Check the output current limit setting
  4. 4Inspect the backup wiring for a partial short

Fixes

  • Reduce the load or split the backup circuits
  • Stagger motor starts and fit soft starters where possible
  • Restart and retest with a known load

When to escalate

If code 49 returns with the measured load inside the inverter rating, escalate for output-stage inspection.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 49 mean?

INV over-current of software: the inverter output current exceeded the software protection limit.

How do I fix Felicity 49?

Reduce the load or split the backup circuits Stagger motor starts and fit soft starters where possible Restart and retest with a known load

When should I escalate Felicity 49?

If code 49 returns with the measured load inside the inverter rating, escalate for output-stage inspection.

Can I reset Felicity 49 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 49 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 49?

Felicity 49 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting