IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 50 error code

INV over-current of hardware: the inverter stage's hardware over-current protection tripped.

Likely causes

  • Fast current surge or short on the output
  • Load beyond the inverter's surge capability
  • Damaged output cable or appliance
  • Internal power-stage fault

Checks to run, in order

  1. 1Disconnect all backup loads and inspect the output wiring
  2. 2Check each appliance for a short
  3. 3Restart with no load, then reconnect loads one at a time
  4. 4Clamp the current during restart

Fixes

  • Clear the short and repair the damaged cable or appliance
  • Reduce the load and restart
  • If the trip happens with no load, book service

When to escalate

A code 50 trip with all loads disconnected indicates an internal power-stage fault - escalate to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 50 mean?

INV over-current of hardware: the inverter stage's hardware over-current protection tripped.

How do I fix Felicity 50?

Clear the short and repair the damaged cable or appliance Reduce the load and restart If the trip happens with no load, book service

When should I escalate Felicity 50?

A code 50 trip with all loads disconnected indicates an internal power-stage fault - escalate to the distributor.

Can I reset Felicity 50 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 50 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 50?

Felicity 50 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.