IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 56 error code

INV short-circuit fault on the inverter AC output.

Likely causes

  • Short circuit in the backup output wiring
  • Shorted appliance or socket on the backup circuit
  • Damaged cable insulation
  • Water in an outdoor socket or junction box

Checks to run, in order

  1. 1Switch off the backup output breaker and disconnect all backup loads
  2. 2Check the backup wiring for a short with an insulation tester
  3. 3Check each appliance and socket on the backup circuit
  4. 4Inspect outdoor joints for water ingress

Fixes

  • Clear the short and repair or replace the damaged cable
  • Reconnect loads one at a time and restart
  • If the fault clears with no load, the wiring was the cause; if not, book service

When to escalate

If code 56 persists with all backup loads disconnected, the inverter output stage has failed - escalate to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 56 mean?

INV short-circuit fault on the inverter AC output.

How do I fix Felicity 56?

Clear the short and repair or replace the damaged cable Reconnect loads one at a time and restart If the fault clears with no load, the wiring was the cause; if not, book service

When should I escalate Felicity 56?

If code 56 persists with all backup loads disconnected, the inverter output stage has failed - escalate to the distributor.

Can I reset Felicity 56 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 56 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 56?

Felicity 56 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.