IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 67 for GEN over-load alarm

Felicity 67 error code

Main and auxiliary DSP communication fault; in the warning list the same number means the generator port is overloaded.

Likely causes

  • Internal communication failure between the main and auxiliary DSP
  • Loose internal ribbon or harness connection
  • Control-board fault
  • For a flashing warning, load on the GEN port above the generator's rating

Checks to run, in order

  1. 1Note whether the fault LED is solid (fault) or flashing (warning)
  2. 2If flashing, compare the GEN-port load with the generator's rated output
  3. 3If solid, restart the inverter 2-3 times and note whether the code returns at once
  4. 4Check for recent firmware changes or a failed update

Fixes

  • For the warning, reduce the GEN-port load or use a larger generator
  • For the fault, restart 2-3 times as the manual directs
  • If it returns, book service - the internal harness is not installer-serviceable

When to escalate

A solid code 67 that persists after restarts is an internal DSP or control-board fault - escalate to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 67 mean?

Main and auxiliary DSP communication fault; in the warning list the same number means the generator port is overloaded.

How do I fix Felicity 67?

For the warning, reduce the GEN-port load or use a larger generator For the fault, restart 2-3 times as the manual directs If it returns, book service - the internal harness is not installer-serviceable

When should I escalate Felicity 67?

A solid code 67 that persists after restarts is an internal DSP or control-board fault - escalate to the distributor.

Can I reset Felicity 67 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 67 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 67?

Felicity 67 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 67 for GEN over-load alarm. Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting