IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 67 for GEN over-load alarm
Felicity 67 error code
Main and auxiliary DSP communication fault; in the warning list the same number means the generator port is overloaded.
Likely causes
- Internal communication failure between the main and auxiliary DSP
- Loose internal ribbon or harness connection
- Control-board fault
- For a flashing warning, load on the GEN port above the generator's rating
Checks to run, in order
- 1Note whether the fault LED is solid (fault) or flashing (warning)
- 2If flashing, compare the GEN-port load with the generator's rated output
- 3If solid, restart the inverter 2-3 times and note whether the code returns at once
- 4Check for recent firmware changes or a failed update
Fixes
- For the warning, reduce the GEN-port load or use a larger generator
- For the fault, restart 2-3 times as the manual directs
- If it returns, book service - the internal harness is not installer-serviceable
When to escalate
A solid code 67 that persists after restarts is an internal DSP or control-board fault - escalate to the distributor.
Fix it with the right tools
Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.
Before you open the inverter
- Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
- Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
- If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.
Questions installers ask
What does Felicity 67 mean?
Main and auxiliary DSP communication fault; in the warning list the same number means the generator port is overloaded.
How do I fix Felicity 67?
For the warning, reduce the GEN-port load or use a larger generator For the fault, restart 2-3 times as the manual directs If it returns, book service - the internal harness is not installer-serviceable
When should I escalate Felicity 67?
A solid code 67 that persists after restarts is an internal DSP or control-board fault - escalate to the distributor.
Can I reset Felicity 67 myself?
Only after isolating the AC and DC sides and running the checks above. If Felicity 67 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.
Which models show Felicity 67?
Felicity 67 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 67 for GEN over-load alarm. Confirm the code on your own unit's display or manual before ordering parts.
More Felicity error codes
- Felicity 04Low cell voltage / over-discharge protection.
- Felicity 05PV over-current fault: the PV input current exceeded the inverter's PV input limit.
- Felicity 18PV short-circuit fault on the PV input; in the warning list the same number means battery under-voltage alarm.
- Felicity 19Battery open-circuit alarm: the inverter no longer detects a battery on its terminals.
- Felicity 20Battery SOC low alarm: the battery's state of charge has fallen to the low-SOC warning threshold.
- Felicity 21BMS communication alarm: abnormal communication between battery and inverter in non-SOC mode.
Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.
Back to troubleshooting