IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 69 error code

EEPROM fault: the inverter could not read or write its stored settings and calibration.

Likely causes

  • EEPROM or control-board failure
  • Settings corrupted by an interrupted write or power loss
  • Surge damage to the control board
  • Firmware fault

Checks to run, in order

  1. 1Record the current settings before any reset
  2. 2Restart 2-3 times and note whether the code returns
  3. 3Check whether a recent settings change or firmware update preceded the fault
  4. 4Note the serial number and firmware version

Fixes

  • Restart as the manual directs
  • If settings are corrupted, have the distributor restore and recalibrate them
  • If the code returns, book control-board service

When to escalate

Code 69 that returns after a restart means the control board cannot store settings - escalate to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 69 mean?

EEPROM fault: the inverter could not read or write its stored settings and calibration.

How do I fix Felicity 69?

Restart as the manual directs If settings are corrupted, have the distributor restore and recalibrate them If the code returns, book control-board service

When should I escalate Felicity 69?

Code 69 that returns after a restart means the control board cannot store settings - escalate to the distributor.

Can I reset Felicity 69 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 69 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 69?

Felicity 69 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting