IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 71 error code

AC leakage current fault: leakage current to earth exceeded the safety limit.

Likely causes

  • Degraded PV cable insulation
  • Ground fault on the PV array or its cabling
  • Water in a PV connector or junction box
  • Missing or poor inverter PE connection
  • Leakage from a damp AC circuit

Checks to run, in order

  1. 1Confirm the inverter PE terminal is bonded to the installation earth
  2. 2Check the PV side cable ground connection as the manual directs
  3. 3Measure PV insulation resistance to earth string by string
  4. 4Inspect connectors and junction boxes for water ingress

Fixes

  • Repair or replace the damaged PV cabling
  • Dry and reseal wet connectors
  • Restore a solid PE bond, then restart 2-3 times
  • If leakage persists, isolate the faulty string and arrange repair

When to escalate

If leakage current returns with a sound earth and dry array, escalate for insulation testing and inverter inspection.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 71 mean?

AC leakage current fault: leakage current to earth exceeded the safety limit.

How do I fix Felicity 71?

Repair or replace the damaged PV cabling Dry and reseal wet connectors Restore a solid PE bond, then restart 2-3 times If leakage persists, isolate the faulty string and arrange repair

When should I escalate Felicity 71?

If leakage current returns with a sound earth and dry array, escalate for insulation testing and inverter inspection.

Can I reset Felicity 71 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 71 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 71?

Felicity 71 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.