IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 74 error code

INV relay self-check fault: an inverter-side safety relay failed its self-check.

Likely causes

  • Failed output relay
  • Relay driver or control-board fault
  • Welded relay contact after a surge
  • Damage after repeated short-circuit trips

Checks to run, in order

  1. 1Restart 2-3 times and note whether the self-check passes
  2. 2Disconnect the backup load and retry
  3. 3Check the output wiring for a short
  4. 4Do not bypass or force the relay

Fixes

  • Restart as the manual directs
  • If the self-check still fails, remove the unit from service
  • Book relay or control-board service

When to escalate

Code 74 is a safety-relay failure - escalate to the distributor; do not bypass the relay.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 74 mean?

INV relay self-check fault: an inverter-side safety relay failed its self-check.

How do I fix Felicity 74?

Restart as the manual directs If the self-check still fails, remove the unit from service Book relay or control-board service

When should I escalate Felicity 74?

Code 74 is a safety-relay failure - escalate to the distributor; do not bypass the relay.

Can I reset Felicity 74 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 74 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 74?

Felicity 74 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting