IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 82 error code

NTC open-circuit fault: an internal temperature sensor reads open circuit.

Likely causes

  • NTC sensor unplugged or its harness damaged
  • Failed NTC thermistor
  • Control-board connector fault
  • Moisture or corrosion on the sensor connector

Checks to run, in order

  1. 1Restart the inverter 2-3 times and note whether the code returns immediately
  2. 2Check the installation for overheating or a fan fault that may have stressed the sensor
  3. 3Arrange an installer inspection of the NTC harness and connectors

Fixes

  • Restart as the manual directs
  • If the code returns, remove the unit from service and book repair
  • Do not bypass the temperature sensor

When to escalate

Code 82 is an internal sensor fault that is not installer-serviceable - escalate to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 82 mean?

NTC open-circuit fault: an internal temperature sensor reads open circuit.

How do I fix Felicity 82?

Restart as the manual directs If the code returns, remove the unit from service and book repair Do not bypass the temperature sensor

When should I escalate Felicity 82?

Code 82 is an internal sensor fault that is not installer-serviceable - escalate to the distributor.

Can I reset Felicity 82 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 82 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 82?

Felicity 82 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting