IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 85 error code

External CT sensor fault: the external current transformer is not giving a usable reading.

Likely causes

  • CT not connected or plugged into the wrong port
  • CT clamped on the wrong conductor or facing the wrong way
  • Damaged CT cable or connector
  • CT ratio or meter setting incorrect

Checks to run, in order

  1. 1Check that the CT is firmly connected to the inverter's CT port
  2. 2Confirm the CT is on the correct conductor and arrow direction
  3. 3Inspect the CT cable and connector for damage
  4. 4Check the CT ratio and meter setting

Fixes

  • Reseat or replace the CT cable
  • Refit the CT on the correct conductor in the right direction
  • Correct the CT ratio setting, then restart

When to escalate

If code 85 persists with a known-good CT and correct settings, escalate for meter/CT-port service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 85 mean?

External CT sensor fault: the external current transformer is not giving a usable reading.

How do I fix Felicity 85?

Reseat or replace the CT cable Refit the CT on the correct conductor in the right direction Correct the CT ratio setting, then restart

When should I escalate Felicity 85?

If code 85 persists with a known-good CT and correct settings, escalate for meter/CT-port service.

Can I reset Felicity 85 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 85 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 85?

Felicity 85 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting