IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 89 error code

Parallel CAN communication failure: the CAN link between parallel inverters failed.

Likely causes

  • Parallel CAN cable loose or damaged
  • Missing or incorrect 120 ohm termination
  • Duplicate or wrong CAN address
  • One inverter powered down

Checks to run, in order

  1. 1Check the parallel CAN cables at every unit
  2. 2Confirm the 120 ohm termination is fitted as the manual requires
  3. 3Check each inverter's CAN address is unique
  4. 4Confirm every unit in the group is powered

Fixes

  • Reseat or replace the CAN cable
  • Fit the correct termination
  • Correct the addresses and restart the group

When to escalate

If the CAN wiring and termination are correct and code 89 persists, escalate for communication-board service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 89 mean?

Parallel CAN communication failure: the CAN link between parallel inverters failed.

How do I fix Felicity 89?

Reseat or replace the CAN cable Fit the correct termination Correct the addresses and restart the group

When should I escalate Felicity 89?

If the CAN wiring and termination are correct and code 89 persists, escalate for communication-board service.

Can I reset Felicity 89 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 89 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 89?

Felicity 89 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.