IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 91 for push-button shutdown alarm

Felicity 91 error code

Parallel sync signal lost (solid LED): the parallel inverters lost their synchronisation signal; in the warning list the same number is the push-button shutdown alarm (flashing LED).

Likely causes

  • Parallel synchronisation cable loose or damaged
  • Master inverter offline or faulted
  • Large configuration mismatch in the group
  • The unit's shutdown button was pressed (warning variant)

Checks to run, in order

  1. 1Note whether the fault LED is solid (fault) or flashing (warning)
  2. 2Check the parallel communication and sync cables at every unit
  3. 3Confirm the master is powered and healthy
  4. 4If flashing, check whether the shutdown button was pressed

Fixes

  • Reseat or replace the parallel sync cable
  • Restore the master and restart the group
  • For the warning, restart the unit after checking the button

When to escalate

If the sync wiring and master are healthy but code 91 persists, escalate for parallel-control service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 91 mean?

Parallel sync signal lost (solid LED): the parallel inverters lost their synchronisation signal; in the warning list the same number is the push-button shutdown alarm (flashing LED).

How do I fix Felicity 91?

Reseat or replace the parallel sync cable Restore the master and restart the group For the warning, restart the unit after checking the button

When should I escalate Felicity 91?

If the sync wiring and master are healthy but code 91 persists, escalate for parallel-control service.

Can I reset Felicity 91 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 91 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 91?

Felicity 91 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 91 for push-button shutdown alarm. Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting