IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)

Felicity 95 error code

Parallel PWM signal lost: the PWM synchronisation signal between parallel inverters is missing.

Likely causes

  • Parallel PWM/sync cable loose or damaged
  • Master inverter offline or faulted
  • Damaged communication board
  • Cable run too long or poorly routed near power cables

Checks to run, in order

  1. 1Check the parallel PWM/sync cable at every unit
  2. 2Confirm the master is powered and healthy
  3. 3Inspect the communication board and connectors
  4. 4Re-route the cable away from power conductors if needed

Fixes

  • Reseat or replace the parallel sync cable
  • Restore the master and restart the group
  • If the cable is good, book communication-board service

When to escalate

If code 95 persists with a known-good sync cable and a healthy master, escalate for parallel-control service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity 95 mean?

Parallel PWM signal lost: the PWM synchronisation signal between parallel inverters is missing.

How do I fix Felicity 95?

Reseat or replace the parallel sync cable Restore the master and restart the group If the cable is good, book communication-board service

When should I escalate Felicity 95?

If code 95 persists with a known-good sync cable and a healthy master, escalate for parallel-control service.

Can I reset Felicity 95 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity 95 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity 95?

Felicity 95 is documented for IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting