FLA48200/FLA48300/FLA48500 and LUX-Y low-voltage LiFePO4 batteries (BMS fault code list)

Felicity C05 error code

Charge over-current: charging current exceeded the BMS limit for about 15 seconds.

Likely causes

  • Charge current setting too high
  • PV and grid charging together exceeding the pack limit
  • Battery bank too small for the charge source
  • BMS current measurement fault

Checks to run, in order

  1. 1Read the charge current on the battery display or app
  2. 2Compare it with the battery's maximum charge current
  3. 3Check the inverter charge current setting
  4. 4Check whether PV and grid are charging simultaneously

Fixes

  • Reduce the charge current to the battery rating
  • Disable one charge source if both are active
  • Restart the unit; if the error persists, contact the repair centre

When to escalate

If charge current is within the battery rating and C05 returns, escalate for BMS service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity C05 mean?

Charge over-current: charging current exceeded the BMS limit for about 15 seconds.

How do I fix Felicity C05?

Reduce the charge current to the battery rating Disable one charge source if both are active Restart the unit; if the error persists, contact the repair centre

When should I escalate Felicity C05?

If charge current is within the battery rating and C05 returns, escalate for BMS service.

Can I reset Felicity C05 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity C05 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity C05?

Felicity C05 is documented for FLA48200/FLA48300/FLA48500 and LUX-Y low-voltage LiFePO4 batteries (BMS fault code list). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.