FLA48200/FLA48300/FLA48500 and LUX-Y low-voltage LiFePO4 batteries (BMS fault code list)

Felicity C06 error code

Discharge over-current: discharge current exceeded the BMS limit for about 15 seconds.

Likely causes

  • Load drawing more than the battery's discharge limit
  • Large motor or compressor inrush
  • Inverter discharge current setting too high
  • Short or near-short on the battery output

Checks to run, in order

  1. 1Read the discharge current on the battery display or app
  2. 2Compare it with the battery's maximum discharge current
  3. 3Review the connected load and motor starting
  4. 4Inspect battery output wiring for a short

Fixes

  • Shed load or reduce the inverter's discharge current limit
  • Stagger motor starts
  • Restart the unit; if the error persists, contact the repair centre

When to escalate

If discharge current is within the battery rating and C06 returns, escalate for BMS or pack inspection.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Felicity C06 mean?

Discharge over-current: discharge current exceeded the BMS limit for about 15 seconds.

How do I fix Felicity C06?

Shed load or reduce the inverter's discharge current limit Stagger motor starts Restart the unit; if the error persists, contact the repair centre

When should I escalate Felicity C06?

If discharge current is within the battery rating and C06 returns, escalate for BMS or pack inspection.

Can I reset Felicity C06 myself?

Only after isolating the AC and DC sides and running the checks above. If Felicity C06 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Felicity C06?

Felicity C06 is documented for FLA48200/FLA48300/FLA48500 and LUX-Y low-voltage LiFePO4 batteries (BMS fault code list). Confirm the code on your own unit's display or manual before ordering parts.

More Felicity error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting