IPV Pro series (IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter fault code
Itel Energy 42 error code
The inverter detected abnormal PV input power.
Likely causes
- Unstable or fluctuating PV input
- String or module fault producing abnormal power readings
- PV current or voltage sensing fault
Checks to run, in order
- 1Read PV voltage, current and power on the LCD and compare with the array expectation
- 2Check string connections and irradiance at the time of the fault
- 3Restart and observe whether the code returns
Fixes
- Correct the faulty string wiring or module
- Restart the inverter
- If readings remain abnormal, return the unit for service
When to escalate
If PV readings are normal when code 42 appears, escalate for PV sensing service.
Fix it with the right tools
Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.
Before you open the inverter
- Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
- Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
- If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.
Questions installers ask
What does Itel Energy 42 mean?
The inverter detected abnormal PV input power.
How do I fix Itel Energy 42?
Correct the faulty string wiring or module Restart the inverter If readings remain abnormal, return the unit for service
When should I escalate Itel Energy 42?
If PV readings are normal when code 42 appears, escalate for PV sensing service.
Can I reset Itel Energy 42 myself?
Only after isolating the AC and DC sides and running the checks above. If Itel Energy 42 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.
Which models show Itel Energy 42?
Itel Energy 42 is documented for IPV Pro series (IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter fault code. Confirm the code on your own unit's display or manual before ordering parts.
More Itel Energy error codes
- Itel Energy 01Display code 01 covers two events: as a warning it signals output overload (flashing fault LED, two beeps per second); as a fault it signals DC bus over-voltage (solid fault LED, output switched off).
- Itel Energy 02Display code 02 covers two events: as a warning it signals the upper cooling fan is locked (three beeps); as a fault it signals DC bus under-voltage (solid fault LED, output switched off).
- Itel Energy 03Display code 03 covers two events: as a warning it signals the lower cooling fan is locked (three beeps); as a fault it signals that the DC bus soft-start sequence failed (solid fault LED).
- Itel Energy 04Grid voltage is above the upper limit of the inverter's grid window; warning only, with no buzzer alarm.
- Itel Energy 05In a parallel system the AC outputs of the units are not connected together, or a unit is running on a different phase.
- Itel Energy 06Remote shutdown is enabled, typically from the monitoring app over Wi-Fi, so the inverter is being held off remotely.
Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.
Back to troubleshooting