Anern AN-SCI-EVO OEM series (SMS 2 kVA/12 V, 4.2 kW/24 V, 10.2 kVA/48 V hybrid units)

SMS Sunmate Solar 55 error code

Asymmetric AC output: DC voltage is present on the AC output, so the output waveform is not symmetrical.

Likely causes

  • Faulty inverter output stage
  • A faulty appliance feeding DC or a half-wave load back onto the output
  • Measurement taken with a non-true-RMS meter

Checks to run, in order

  1. 1Measure the output voltage L-N with a true-RMS meter
  2. 2Disconnect all loads and re-measure
  3. 3Check for appliances with half-wave rectifiers or a failing power supply
  4. 4Restart and see whether 55 returns with no load

Fixes

  • Remove the suspect appliance and retest
  • Restart the inverter once the output is clear
  • Replace any output accessory showing DC leakage

When to escalate

If 55 persists with no load on a true-RMS meter, the output stage is faulty — return the inverter for service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does SMS Sunmate Solar 55 mean?

Asymmetric AC output: DC voltage is present on the AC output, so the output waveform is not symmetrical.

How do I fix SMS Sunmate Solar 55?

Remove the suspect appliance and retest Restart the inverter once the output is clear Replace any output accessory showing DC leakage

When should I escalate SMS Sunmate Solar 55?

If 55 persists with no load on a true-RMS meter, the output stage is faulty — return the inverter for service.

Can I reset SMS Sunmate Solar 55 myself?

Only after isolating the AC and DC sides and running the checks above. If SMS Sunmate Solar 55 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show SMS Sunmate Solar 55?

SMS Sunmate Solar 55 is documented for Anern AN-SCI-EVO OEM series (SMS 2 kVA/12 V, 4.2 kW/24 V, 10.2 kVA/48 V hybrid units). Confirm the code on your own unit's display or manual before ordering parts.

More SMS Sunmate Solar error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.