HESP series hybrid inverters (single-phase 4-12 kW and three-phase 8-12 kW)

SRNE 30 error code

Battery capacity low alarm 1 (BatCapacityLow1): BMS reports SOC below the first low-capacity threshold, 10 percent in the single-phase table and 15 percent in the three-phase table.

Likely causes

  • Battery discharged to the low-capacity threshold
  • Insufficient PV or grid charging
  • BMS protocol not enabled so SOC is unavailable
  • Load larger than the daily charge budget

Checks to run, in order

  1. 1Read SOC from the inverter display and the BMS app
  2. 2Confirm BMS communication is working
  3. 3Check PV yield and AC charge settings
  4. 4Review the load profile against the charge available

Fixes

  • Charge the battery above the alarm SOC
  • Shift heavy loads to daylight hours
  • Confirm the lithium protocol is selected so SOC limits work

When to escalate

If SOC is reported incorrectly against the BMS, the distributor should check the BMS protocol mapping; the threshold itself is a BMS setting, not an inverter fault.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does SRNE 30 mean?

Battery capacity low alarm 1 (BatCapacityLow1): BMS reports SOC below the first low-capacity threshold, 10 percent in the single-phase table and 15 percent in the three-phase table.

How do I fix SRNE 30?

Charge the battery above the alarm SOC Shift heavy loads to daylight hours Confirm the lithium protocol is selected so SOC limits work

When should I escalate SRNE 30?

If SOC is reported incorrectly against the BMS, the distributor should check the BMS protocol mapping; the threshold itself is a BMS setting, not an inverter fault.

Can I reset SRNE 30 myself?

Only after isolating the AC and DC sides and running the checks above. If SRNE 30 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show SRNE 30?

SRNE 30 is documented for HESP series hybrid inverters (single-phase 4-12 kW and three-phase 8-12 kW). Confirm the code on your own unit's display or manual before ordering parts.

More SRNE error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.