SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table)

Deye F06 error code

Control-board EEPROM write failure.

Likely causes

  • Write-protected or corrupted EEPROM
  • Firmware update interrupted while saving settings
  • Control-board supply glitch or EMI
  • Failed control board

Checks to run, in order

  1. 1Record the current settings and firmware version
  2. 2Power-cycle the inverter from DC and AC
  3. 3Re-check whether settings are retained after restart

Fixes

  • Restart the inverter three times
  • Restore factory settings and re-enter the site configuration
  • Re-apply the correct firmware

When to escalate

If settings cannot be saved and F06 persists, the control board must be replaced by the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Deye F06 mean?

Control-board EEPROM write failure.

How do I fix Deye F06?

Restart the inverter three times Restore factory settings and re-enter the site configuration Re-apply the correct firmware

When should I escalate Deye F06?

If settings cannot be saved and F06 persists, the control board must be replaced by the distributor.

Can I reset Deye F06 myself?

Only after isolating the AC and DC sides and running the checks above. If Deye F06 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Deye F06?

Deye F06 is documented for SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table). Confirm the code on your own unit's display or manual before ordering parts.

More Deye error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting