SG04LP3/SG05LP1 hybrid families and SG01HP3-EU-DM2

Deye F07 error code

DC-DC stage 1 could not raise the bus voltage from PV or battery.

Likely causes

  • DC switch open or DC breaker tripped
  • PV or battery voltage below the start-up threshold
  • Blown DC fuse or open DC isolator
  • Battery BMS contactor not closed

Checks to run, in order

  1. 1Confirm the DC switch and battery breaker are closed
  2. 2Measure battery and PV voltage at the inverter DC terminals
  3. 3Check the DC fuses and isolator
  4. 4Check BMS communication and battery breaker state

Fixes

  • Close the DC switch or breaker and reset the fuse
  • Charge the battery or wait for sufficient PV voltage
  • Restore BMS communication
  • Restart the inverter

When to escalate

If DC voltages are within range and F07 persists, the DC-DC stage needs distributor service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Deye F07 mean?

DC-DC stage 1 could not raise the bus voltage from PV or battery.

How do I fix Deye F07?

Close the DC switch or breaker and reset the fuse Charge the battery or wait for sufficient PV voltage Restore BMS communication Restart the inverter

When should I escalate Deye F07?

If DC voltages are within range and F07 persists, the DC-DC stage needs distributor service.

Can I reset Deye F07 myself?

Only after isolating the AC and DC sides and running the checks above. If Deye F07 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Deye F07?

Deye F07 is documented for SG04LP3/SG05LP1 hybrid families and SG01HP3-EU-DM2. Confirm the code on your own unit's display or manual before ordering parts.