SG04LP3/SG05LP1 hybrid families and SG01HP3-EU-DM2

Deye F08 error code

DC-DC stage 2 could not raise the bus voltage from PV or battery.

Likely causes

  • Second PV input or battery feed below the start-up threshold
  • Open DC switch, breaker or fuse on the second input
  • Battery BMS contactor not closed
  • Fault in the second DC-DC stage

Checks to run, in order

  1. 1Confirm the second DC input switch and breaker are closed
  2. 2Measure PV and battery voltage at the second input
  3. 3Check the DC fuses on that input
  4. 4Check BMS communication and battery state

Fixes

  • Close the switch or breaker and reset the fuse
  • Charge the battery or wait for sufficient PV voltage
  • Restart the inverter

When to escalate

If the second input has correct voltage and F08 persists, the DC-DC stage needs distributor service.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Deye F08 mean?

DC-DC stage 2 could not raise the bus voltage from PV or battery.

How do I fix Deye F08?

Close the switch or breaker and reset the fuse Charge the battery or wait for sufficient PV voltage Restart the inverter

When should I escalate Deye F08?

If the second input has correct voltage and F08 persists, the DC-DC stage needs distributor service.

Can I reset Deye F08 myself?

Only after isolating the AC and DC sides and running the checks above. If Deye F08 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Deye F08?

Deye F08 is documented for SG04LP3/SG05LP1 hybrid families and SG01HP3-EU-DM2. Confirm the code on your own unit's display or manual before ordering parts.

More Deye error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting