SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table)

Deye F09 error code

IGBT power-stage failure detected.

Likely causes

  • IGBT or gate-driver failure
  • AC output short circuit or severe overload
  • Power-stage overheating
  • DC bus overvoltage event

Checks to run, in order

  1. 1Check the AC output and downstream wiring for a short
  2. 2Check the load and ambient temperature
  3. 3Power-cycle and read the fault history
  4. 4Compare the DC bus and battery voltage with the specification

Fixes

  • Clear any output short and reduce the load
  • Restart once after the unit has cooled

When to escalate

IGBT failures are not field-repairable; stop and return the inverter to the distributor.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Deye F09 mean?

IGBT power-stage failure detected.

How do I fix Deye F09?

Clear any output short and reduce the load Restart once after the unit has cooled

When should I escalate Deye F09?

IGBT failures are not field-repairable; stop and return the inverter to the distributor.

Can I reset Deye F09 myself?

Only after isolating the AC and DC sides and running the checks above. If Deye F09 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Deye F09?

Deye F09 is documented for SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table). Confirm the code on your own unit's display or manual before ordering parts.

More Deye error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.