SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table)
Deye F32 error code
DC overcurrent on MPPT input 2.
Likely causes
- PV overcurrent on MPPT 2
- Shorted string on MPPT 2
- M2 current sensor fault
Checks to run, in order
- 1Measure the MPPT 2 string current
- 2Check the MPPT 2 wiring for a short
- 3Restart the inverter
Fixes
- Reduce the strings on MPPT 2
- Repair the PV wiring
- Restart and restore factory settings
When to escalate
If MPPT 2 current is within specification and F32 persists, the distributor should test the M2 current sensor.
Fix it with the right tools
Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.
Before you open the inverter
- Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
- Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
- If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.
Questions installers ask
What does Deye F32 mean?
DC overcurrent on MPPT input 2.
How do I fix Deye F32?
Reduce the strings on MPPT 2 Repair the PV wiring Restart and restore factory settings
When should I escalate Deye F32?
If MPPT 2 current is within specification and F32 persists, the distributor should test the M2 current sensor.
Can I reset Deye F32 myself?
Only after isolating the AC and DC sides and running the checks above. If Deye F32 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.
Which models show Deye F32?
Deye F32 is documented for SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table). Confirm the code on your own unit's display or manual before ordering parts.
More Deye error codes
- Deye F01PV input polarity is reversed at one or both DC inputs.
- Deye F02PV insulation resistance to earth is below the safety limit.
- Deye F03Ground fault detected on the PV array (GFDI).
- Deye F04GFDI ground-failure alarm: the PV array or inverter is not properly earthed.
- Deye F05Control-board EEPROM read failure.
- Deye F06Control-board EEPROM write failure.