SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table)

Deye F54 error code

Battery 2 terminal voltage too high.

Likely causes

  • Overvoltage on the second battery bank
  • BMS charge limit set too high
  • Wrong battery count or voltage setting
  • Voltage-sensing or wiring fault

Checks to run, in order

  1. 1Measure the battery 2 terminal voltage
  2. 2Compare with the BMS charge limits
  3. 3Check the battery settings
  4. 4Check the battery 2 wiring

Fixes

  • Reduce the charge voltage and current
  • Correct the battery settings
  • Restart twice and restore factory settings

When to escalate

If the battery 2 voltage is within limits and F54 persists, the distributor should check the battery voltage sensing.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Deye F54 mean?

Battery 2 terminal voltage too high.

How do I fix Deye F54?

Reduce the charge voltage and current Correct the battery settings Restart twice and restore factory settings

When should I escalate Deye F54?

If the battery 2 voltage is within limits and F54 persists, the distributor should check the battery voltage sensing.

Can I reset Deye F54 myself?

Only after isolating the AC and DC sides and running the checks above. If Deye F54 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Deye F54?

Deye F54 is documented for SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (F-series table). Confirm the code on your own unit's display or manual before ordering parts.

More Deye error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.