SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (warning codes)

Deye W06 error code

CT not connected.

Likely causes

  • CT leads disconnected
  • Broken CT lead
  • CT landed on the wrong terminal

Checks to run, in order

  1. 1Check the CT plug and terminal
  2. 2Check CT lead continuity
  3. 3Check the CT ratio setting

Fixes

  • Reconnect or replace the CT lead
  • Restart the inverter

When to escalate

If the CT is connected and W06 persists, the distributor should check the CT input circuit.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Deye W06 mean?

CT not connected.

How do I fix Deye W06?

Reconnect or replace the CT lead Restart the inverter

When should I escalate Deye W06?

If the CT is connected and W06 persists, the distributor should check the CT input circuit.

Can I reset Deye W06 myself?

Only after isolating the AC and DC sides and running the checks above. If Deye W06 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Deye W06?

Deye W06 is documented for SUN-5-12K-SG01HP3-EU-DM2 three-phase hybrid (warning codes). Confirm the code on your own unit's display or manual before ordering parts.