SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81)

Growatt 07 error code

Overload time out — the inverter carried over 110% load until its overload timer expired (F07 on the ES Lite).

Likely causes

  • Connected load above the inverter rating
  • Motor or compressor inrush exceeding the rating
  • Too many appliances on the output

Checks to run, in order

  1. 1Add up the connected load against the inverter rating
  2. 2Check for high-inrush appliances
  3. 3Observe whether the fault appears at a particular appliance start

Fixes

  • Reduce the connected load by switching off some equipment
  • Stagger the starting of motor loads
  • Restart the unit after the load is reduced

When to escalate

If the load is within rating and fault 07 recurs, return the unit to a Growatt repair centre.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Growatt 07 mean?

Overload time out — the inverter carried over 110% load until its overload timer expired (F07 on the ES Lite).

How do I fix Growatt 07?

Reduce the connected load by switching off some equipment Stagger the starting of motor loads Restart the unit after the load is reduced

When should I escalate Growatt 07?

If the load is within rating and fault 07 recurs, return the unit to a Growatt repair centre.

Can I reset Growatt 07 myself?

Only after isolating the AC and DC sides and running the checks above. If Growatt 07 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Growatt 07?

Growatt 07 is documented for SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81). Confirm the code on your own unit's display or manual before ordering parts.