SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81)

Growatt 58 error code

Output voltage is too low. The manual groups 06/58 as 'output abnormal' — inverter voltage above 150 Vac or below 40 Vac.

Likely causes

  • Overload dragging the output voltage down
  • Output wiring too thin or too long
  • Output-stage fault

Checks to run, in order

  1. 1Measure the output voltage with a true-RMS meter
  2. 2Reduce the connected load and retry
  3. 3Check output wiring gauge and terminations

Fixes

  • Reduce the connected load
  • Correct the output wiring
  • Restart the unit

When to escalate

If the error happens again after restart, return the unit to a Growatt repair centre.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Growatt 58 mean?

Output voltage is too low. The manual groups 06/58 as 'output abnormal' — inverter voltage above 150 Vac or below 40 Vac.

How do I fix Growatt 58?

Reduce the connected load Correct the output wiring Restart the unit

When should I escalate Growatt 58?

If the error happens again after restart, return the unit to a Growatt repair centre.

Can I reset Growatt 58 myself?

Only after isolating the AC and DC sides and running the checks above. If Growatt 58 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Growatt 58?

Growatt 58 is documented for SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81). Confirm the code on your own unit's display or manual before ordering parts.

More Growatt error codes

Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.

Back to troubleshooting