SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81)

Growatt 80 error code

CAN fault — parallel CAN communication failure (F80 on the ES Lite).

Likely causes

  • Parallel communication cables loose or not connected
  • Program 23 settings wrong for the parallel system
  • One inverter in the parallel stack powered off

Checks to run, in order

  1. 1Check whether the parallel communication cables are connected well
  2. 2Check whether program 23 settings are right for the parallel system
  3. 3Confirm every inverter in the stack is powered on

Fixes

  • Reseat the parallel communication cables
  • Correct program 23 for the parallel configuration
  • Restart the parallel stack

When to escalate

If the problem still exists after these checks, contact a Growatt repair centre.

Fix it with the right tools

Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.

Before you open the inverter

  • Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
  • Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
  • If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.

Questions installers ask

What does Growatt 80 mean?

CAN fault — parallel CAN communication failure (F80 on the ES Lite).

How do I fix Growatt 80?

Reseat the parallel communication cables Correct program 23 for the parallel configuration Restart the parallel stack

When should I escalate Growatt 80?

If the problem still exists after these checks, contact a Growatt repair centre.

Can I reset Growatt 80 myself?

Only after isolating the AC and DC sides and running the checks above. If Growatt 80 returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.

Which models show Growatt 80?

Growatt 80 is documented for SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81). Confirm the code on your own unit's display or manual before ordering parts.