SPH 3000–6000TL BL-UP / SPH 4000–10000TL3 BH-UP hybrid (Error 2xx–6xx codes)
Growatt PairingTime Out error code
The inverter timed out trying to pair with the SP-CT (communication fault).
Likely causes
- SP-CT too far from the inverter
- SP-CT not powered
- SP-CT not put into pairing mode
- Radio interference between SP-CT and inverter
Checks to run, in order
- 1Check the distance between SP-CT and inverter is within the specified range
- 2Check the SP-CT is powered
- 3Restart the inverter and SP-CT
- 4Re-run the CT pairing from the inverter menu
Fixes
- Move the SP-CT closer to the inverter
- Power-cycle the SP-CT and re-pair
- Restart the inverter and confirm the CT reading is live
When to escalate
If the SP-CT is powered, in range and still will not pair, ask Growatt support to replace or service the SP-CT.
Fix it with the right tools
Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.
Before you open the inverter
- Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
- Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
- If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.
Questions installers ask
What does Growatt PairingTime Out mean?
The inverter timed out trying to pair with the SP-CT (communication fault).
How do I fix Growatt PairingTime Out?
Move the SP-CT closer to the inverter Power-cycle the SP-CT and re-pair Restart the inverter and confirm the CT reading is live
When should I escalate Growatt PairingTime Out?
If the SP-CT is powered, in range and still will not pair, ask Growatt support to replace or service the SP-CT.
Can I reset Growatt PairingTime Out myself?
Only after isolating the AC and DC sides and running the checks above. If Growatt PairingTime Out returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.
Which models show Growatt PairingTime Out?
Growatt PairingTime Out is documented for SPH 3000–6000TL BL-UP / SPH 4000–10000TL3 BH-UP hybrid (Error 2xx–6xx codes). Confirm the code on your own unit's display or manual before ordering parts.
More Growatt error codes
- Growatt 01Fan is locked (displayed as F01 on the SPF ES Lite).
- Growatt 02Internal component temperature is over 100 °C (F02 on the ES Lite).
- Growatt 03Battery is over-charged / battery voltage is too high (F03 on the ES Lite).
- Growatt 04Battery voltage low.
- Growatt 05Output is short-circuited (F05 on the ES Lite).
- Growatt 06Output voltage is too high. The manual groups 06/58 as 'output abnormal' — inverter voltage above 150 Vac or below 40 Vac.
Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.
Back to troubleshooting