SPH 3000–6000TL BL-UP / SPH 4000–10000TL3 BH-UP hybrid (Error 2xx–6xx codes)
Growatt PV2 short error code
PV2 input is short-circuited (displayed as 'Pv2 short').
Likely causes
- Shorted PV2 string or connector
- Reversed polarity on PV2
- Damaged panel or DC cable on PV2
- Water ingress in the PV2 connector
Checks to run, in order
- 1Shut the inverter down and isolate PV2
- 2Check the PV2 panel/string for a short with a meter
- 3Inspect PV2 connectors and cable for damage or water
- 4Compare PV2 and PV1 string voltages
Fixes
- Repair or replace the faulty PV2 connector, cable or panel
- Reconnect PV2 with correct polarity
- Restart and confirm PV2 produces normally
When to escalate
If the PV2 string tests normal after shutdown and the message persists, ask Growatt support to check the PV2 input circuit.
Fix it with the right tools
Check the system around the fault before replacing parts: load, battery bank, PV string and commissioning settings. If you need a second opinion, send the code and your inverter model to our team.
Before you open the inverter
- Isolate both the AC and DC sides, then confirm the display is dead before touching terminals.
- Use insulated tools and one hand where possible. DC arcs do not self-extinguish like AC.
- If you see burnt terminals, swollen cells, leaking electrolyte or a burning smell, stop and escalate instead of resetting the fault.
Questions installers ask
What does Growatt PV2 short mean?
PV2 input is short-circuited (displayed as 'Pv2 short').
How do I fix Growatt PV2 short?
Repair or replace the faulty PV2 connector, cable or panel Reconnect PV2 with correct polarity Restart and confirm PV2 produces normally
When should I escalate Growatt PV2 short?
If the PV2 string tests normal after shutdown and the message persists, ask Growatt support to check the PV2 input circuit.
Can I reset Growatt PV2 short myself?
Only after isolating the AC and DC sides and running the checks above. If Growatt PV2 short returns immediately, stop resetting it and escalate; a repeating fault usually points to a real circuit, battery or hardware problem.
Which models show Growatt PV2 short?
Growatt PV2 short is documented for SPH 3000–6000TL BL-UP / SPH 4000–10000TL3 BH-UP hybrid (Error 2xx–6xx codes). Confirm the code on your own unit's display or manual before ordering parts.
More Growatt error codes
- Growatt 01Fan is locked (displayed as F01 on the SPF ES Lite).
- Growatt 02Internal component temperature is over 100 °C (F02 on the ES Lite).
- Growatt 03Battery is over-charged / battery voltage is too high (F03 on the ES Lite).
- Growatt 04Battery voltage low.
- Growatt 05Output is short-circuited (F05 on the ES Lite).
- Growatt 06Output voltage is too high. The manual groups 06/58 as 'output abnormal' — inverter voltage above 150 Vac or below 40 Vac.
Guidance reviewed 17 October 2026 by the Mishka Energy installer team. Error codes vary by brand, model family and firmware; confirm against the manufacturer manual.
Back to troubleshooting