Error code library · 34 codes
LVTopsun error codes
Every LVTopsun error and fault code we have documented for LVTS-5220-HVX high-voltage battery - BMS alarm page on the battery touchscreen (LVTOPSUN BMS protection alarms). Each code has its own guide: what it means, the likely causes, checks to run in order, fixes and when to escalate. Compiled from LVTopsun manuals; always confirm the code on your own unit and firmware.
LVTS-5220-HVX high-voltage battery - BMS alarm page on the battery touchscreen (LVTOPSUN BMS protection alarms)34 codes
- LVTopsun Ahesion FltThe BMS detected a main contactor or relay that has stuck closed (contact adhesion).
- LVTopsun Chg Bat Ov_VThe pack voltage rose above the BMS charge over-voltage limit.
- LVTopsun Chg Bat Ud_VPack voltage stayed below the BMS charge under-voltage limit while the pack was supposed to be charging.
- LVTopsun Chg Cell Ov_VCharging was stopped because a cell reached the BMS charge over-voltage limit.
- LVTopsun Chg Cell Ud_VA cell fell below the BMS charge under-voltage limit while the pack was being charged.
- LVTopsun Chg Diff_TThe temperature difference between BMS sensors exceeded the limit during charge.
- LVTopsun Chg Diff_VThe voltage difference between the highest and lowest cell exceeded the BMS limit during charge.
- LVTopsun Chg Ov_CCharge current exceeded the BMS limit.
- LVTopsun Chg Ov_TCell or module temperature exceeded the BMS charge over-temperature limit.
- LVTopsun Chg Ud_TBattery temperature was below the BMS charging window, so charging was blocked.
- LVTopsun ChgRly OTThe charge relay temperature exceeded the BMS limit.
- LVTopsun Commu FltThe BMS lost communication with the inverter or with another module in the stack.
- LVTopsun Danger OTTemperature entered the BMS danger over-temperature range.
- LVTopsun Danger OVPack or cell voltage entered the BMS danger over-voltage range.
- LVTopsun Danger UTTemperature entered the BMS danger under-temperature range.
- LVTopsun Danger UVPack or cell voltage entered the BMS danger (second-level) under-voltage range.
- LVTopsun Dsg Bat Ov_VPack voltage rose above the BMS discharge over-voltage limit.
- LVTopsun Dsg Bat Ud_VPack voltage fell below the BMS discharge under-voltage limit.
- LVTopsun Dsg Cell Ov_VA cell rose above the BMS discharge over-voltage limit while the pack was discharging.
- LVTopsun Dsg Cell Ud_VA cell fell below the BMS discharge under-voltage limit.
- LVTopsun Dsg Diff_TThe temperature difference between BMS sensors exceeded the limit during discharge.
- LVTopsun Dsg Diff_VCell voltage spread exceeded the BMS limit during discharge.
- LVTopsun Dsg Ov_CDischarge current exceeded the BMS limit.
- LVTopsun Dsg Ov_TCell or module temperature exceeded the BMS discharge over-temperature limit.
- LVTopsun Dsg Ud_TBattery temperature was below the BMS discharge window, so discharge was blocked.
- LVTopsun DsgRly OTThe discharge relay temperature exceeded the BMS limit.
- LVTopsun Fdback OCThe BMS detected an over-current in its current-feedback circuit.
- LVTopsun Insu LowInsulation resistance between the high-voltage DC circuit and earth fell below the BMS limit.
- LVTopsun Prechg FltThe pre-charge circuit did not bring the DC bus up as expected before the main contactor closed.
- LVTopsun SelfChk FltThe BMS power-on self-check failed.
- LVTopsun SmplTemp FltThe BMS temperature sampling circuit reported a fault.
- LVTopsun SmplVolt FltThe BMS voltage sampling circuit reported a fault, so the cell readings are unreliable.
- LVTopsun SOC LowState of charge fell below the BMS low-SOC warning threshold.
- LVTopsun System FltThe BMS reported an internal system fault that is not covered by a specific alarm.
Before you reset a LVTopsun fault
- 1Write down the exact code and any letter before it, and check which LVTopsun model is showing it. The same number can mean different faults on an inverter and on a battery.
- 2Isolate the AC and DC sides before touching terminals, then run the checks on the code's page in order.
- 3If the code comes straight back after a reset, stop resetting it. A repeating fault points to a real wiring, battery or hardware problem.