Error code library · 76 codes
Felicity error codes
Every Felicity error and fault code we have documented for Lithium battery BMS, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED), IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 18 for battery under-voltage alarm, IVGM5-8K LP2G1 hybrid inverters (warning code list, flashing fault LED), IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 35 for grid over-frequency alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 43 for active-islanding alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 44 for low-voltage ride-through alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 57 for generator over-voltage alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 58 for generator under-voltage alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 67 for GEN over-load alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 86 for fan 1 failed alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 87 for fan 2 failed alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 91 for push-button shutdown alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 92 for remote shutdown alarm, IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 93 for flash-not-burned alarm and FLA48200/FLA48300/FLA48500 and LUX-Y low-voltage LiFePO4 batteries (BMS fault code list). Each code has its own guide: what it means, the likely causes, checks to run in order, fixes and when to escalate. Compiled from Felicity manuals; always confirm the code on your own unit and firmware.
Lithium battery BMS1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED)36 codes
- Felicity 05PV over-current fault: the PV input current exceeded the inverter's PV input limit.
- Felicity 25Battery over-voltage fault: the battery voltage exceeded the inverter's specification.
- Felicity 27Battery over-current fault: current into or out of the battery exceeded the inverter's protection limit.
- Felicity 28Battery hardware over-current: the battery port's hardware protection tripped on an instantaneous over-current.
- Felicity 31LLC over-current fault of hardware: the hardware protection on the LLC converter stage tripped.
- Felicity 32BMS communication fault: the inverter cannot communicate with the battery BMS.
- Felicity 37LLC soft-start failure: the LLC converter did not reach its working point during soft start.
- Felicity 40Battery short-circuit fault detected on the battery port.
- Felicity 41BUS over-voltage fault: the internal DC bus voltage exceeded its protection ceiling.
- Felicity 49INV over-current of software: the inverter output current exceeded the software protection limit.
- Felicity 50INV over-current of hardware: the inverter stage's hardware over-current protection tripped.
- Felicity 51INV soft-start failure: the inverter output stage did not ramp up during soft start.
- Felicity 52AC voltage DC-component fault: a DC offset was detected on the inverter's AC output voltage.
- Felicity 53AC current DC-component fault: a DC component was detected in the inverter's AC output current.
- Felicity 54INV over-voltage fault: the inverter's AC output voltage exceeded its permitted range.
- Felicity 55INV under-voltage fault: the inverter's AC output voltage fell below its permitted range.
- Felicity 56INV short-circuit fault on the inverter AC output.
- Felicity 65Heatsink over-temperature fault: the inverter's internal temperature exceeded the safe operating threshold.
- Felicity 68MCU communication fault: the inverter's MCU communication link failed.
- Felicity 69EEPROM fault: the inverter could not read or write its stored settings and calibration.
- Felicity 70AC leakage current sensor fault: the leakage-current sensor returned an implausible reading.
- Felicity 71AC leakage current fault: leakage current to earth exceeded the safety limit.
- Felicity 72Grid relay open-circuit fault: a grid-side safety relay failed its self-check or is stuck open.
- Felicity 74INV relay self-check fault: an inverter-side safety relay failed its self-check.
- Felicity 76GEN relay self-check fault: the generator-side safety relay failed its self-check.
- Felicity 77PV insulation impedance fault: the PV array's resistance to earth is below the safe threshold.
- Felicity 78Grid wrongly connected to the backup port: grid voltage is present on the backup (load) terminals.
- Felicity 79Generator port wrongly connected: the GEN port is set to smart-load mode but a generator or grid source is connected to it.
- Felicity 82NTC open-circuit fault: an internal temperature sensor reads open circuit.
- Felicity 85External CT sensor fault: the external current transformer is not giving a usable reading.
- Felicity 88Parallel system error: another inverter in the parallel system is in an error state.
- Felicity 89Parallel CAN communication failure: the CAN link between parallel inverters failed.
- Felicity 90Parallel host lost: the master inverter in the parallel system is not responding.
- Felicity 94CAN ID conflict: two inverters in the parallel system share a CAN ID, or two masters exist in one phase.
- Felicity 95Parallel PWM signal lost: the PWM synchronisation signal between parallel inverters is missing.
- Felicity 96Phase sequence abnormal: the phase order at the grid input is incorrect.
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 18 for battery under-voltage alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (warning code list, flashing fault LED)13 codes
- Felicity 19Battery open-circuit alarm: the inverter no longer detects a battery on its terminals.
- Felicity 20Battery SOC low alarm: the battery's state of charge has fallen to the low-SOC warning threshold.
- Felicity 21BMS communication alarm: abnormal communication between battery and inverter in non-SOC mode.
- Felicity 22Battery under-voltage alarm or battery SOC low alarm: battery voltage is too low, or the BMS reports SOC too low, and the battery should be charged.
- Felicity 33Grid over-voltage alarm: grid voltage is above the inverter's permitted operating window.
- Felicity 34Grid under-voltage alarm: grid voltage is below the inverter's permitted operating window.
- Felicity 36Grid under-frequency alarm: grid frequency is below the inverter's permitted operating window.
- Felicity 38Grid reverse-sequence alarm: the phase order at the grid input is reversed.
- Felicity 48Backup overload alarm: the load on the backup output is above the inverter's continuous rating and should be reduced.
- Felicity 59Generator over-frequency alarm: generator frequency is above the inverter's permitted range.
- Felicity 60Generator under-frequency alarm: generator frequency is below the inverter's permitted range.
- Felicity 62Generator reverse-sequence alarm: the phase order at the generator input is reversed.
- Felicity 83Radiator over-temperature derating alarm: the inverter is reducing power because the heatsink temperature is too high.
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 35 for grid over-frequency alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 43 for active-islanding alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 44 for low-voltage ride-through alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 57 for generator over-voltage alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 58 for generator under-voltage alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 67 for GEN over-load alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 86 for fan 1 failed alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 87 for fan 2 failed alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 91 for push-button shutdown alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 92 for remote shutdown alarm1 codes
IVGM5-8K LP2G1 hybrid inverters (fault code list, solid fault LED); warning list uses 93 for flash-not-burned alarm1 codes
FLA48200/FLA48300/FLA48500 and LUX-Y low-voltage LiFePO4 batteries (BMS fault code list)14 codes
- Felicity C01Battery over-voltage: total pack voltage exceeded the BMS upper protection limit.
- Felicity C02Battery under-voltage: total pack voltage dropped below the BMS lower protection limit.
- Felicity C03Cell over-voltage: an individual cell exceeded its upper voltage limit.
- Felicity C04Cell under-voltage: an individual cell dropped below its lower voltage limit.
- Felicity C05Charge over-current: charging current exceeded the BMS limit for about 15 seconds.
- Felicity C06Discharge over-current: discharge current exceeded the BMS limit for about 15 seconds.
- Felicity C07MOS over-temperature: the BMS MOSFET temperature is above its limit.
- Felicity C08MOS under-temperature: the BMS MOSFET temperature is below its operating limit.
- Felicity C09Cell over-temperature: a cell temperature exceeded its upper limit.
- Felicity C10Cell under-temperature: a cell temperature is below its lower limit.
- Felicity C11Abnormal current sampling: the BMS current measurement is implausible.
- Felicity C12Abnormal output impedance: the BMS measured an unexpected output impedance.
- Felicity C13Parallel failed: the battery could not establish parallel communication or balance with the other packs.
- Felicity C14Output loss: the battery is not delivering power to the load.
Before you reset a Felicity fault
- 1Write down the exact code and any letter before it, and check which Felicity model is showing it. The same number can mean different faults on an inverter and on a battery.
- 2Isolate the AC and DC sides before touching terminals, then run the checks on the code's page in order.
- 3If the code comes straight back after a reset, stop resetting it. A repeating fault points to a real wiring, battery or hardware problem.