Error code library · 42 codes
Growatt error codes
Every Growatt error and fault code we have documented for SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81), Off-grid / hybrid inverters and SPH 3000–6000TL BL-UP / SPH 4000–10000TL3 BH-UP hybrid (Error 2xx–6xx codes). Each code has its own guide: what it means, the likely causes, checks to run in order, fixes and when to escalate. Compiled from Growatt manuals; always confirm the code on your own unit and firmware.
SPF 3000TL LVM-ES / SPF 3500–5000 ES Lite off-grid (fault codes 01–81)18 codes
- Growatt 01Fan is locked (displayed as F01 on the SPF ES Lite).
- Growatt 02Internal component temperature is over 100 °C (F02 on the ES Lite).
- Growatt 03Battery is over-charged / battery voltage is too high (F03 on the ES Lite).
- Growatt 05Output is short-circuited (F05 on the ES Lite).
- Growatt 06Output voltage is too high. The manual groups 06/58 as 'output abnormal' — inverter voltage above 150 Vac or below 40 Vac.
- Growatt 07Overload time out — the inverter carried over 110% load until its overload timer expired (F07 on the ES Lite).
- Growatt 08DC bus voltage is too high.
- Growatt 09Bus soft start failed / internal components failed. The LVM-ES manual groups 09, 53 and 57 as 'internal components failed'; 53 is inverter soft start failed and 57 is current sensor failed.
- Growatt 51Over current or surge on the output (F51 on the ES Lite).
- Growatt 52DC bus voltage is too low (F52 on the ES Lite).
- Growatt 55Over DC voltage in the AC output / output voltage unbalanced (F55 on the ES Lite).
- Growatt 56Battery connection is open or the battery fuse is burnt (F56 on the ES Lite).
- Growatt 58Output voltage is too low. The manual groups 06/58 as 'output abnormal' — inverter voltage above 150 Vac or below 40 Vac.
- Growatt 60Negative power fault — power is flowing back into the AC input (F60 on the ES Lite).
- Growatt 61PV voltage is too high (F61 on the ES Lite).
- Growatt 62Internal communication error (F62 on the ES Lite).
- Growatt 80CAN fault — parallel CAN communication failure (F80 on the ES Lite).
- Growatt 81Host loss — the parallel system has lost the host inverter (F81 on the ES Lite).
Off-grid / hybrid inverters1 codes
SPH 3000–6000TL BL-UP / SPH 4000–10000TL3 BH-UP hybrid (Error 2xx–6xx codes)23 codes
- Growatt CT LN ReversedThe CT is connected with line and neutral reversed, or its PE reference is missing.
- Growatt Error 202PV input voltage is above the inverter's maximum DC input voltage.
- Growatt Error 203PV array insulation resistance to earth is below the inverter's isolation threshold.
- Growatt Error 300Grid voltage is outside the inverter's configured grid-voltage window. The three-phase BH-UP manual shows variants AC V Outrange (1), (2) and (3) with the same checks.
- Growatt Error 302The inverter sees no AC grid connection at its input.
- Growatt Error 304Grid frequency is outside the inverter's configured frequency window.
- Growatt Error 402DC component in the AC output current exceeds the disconnection threshold.
- Growatt Error 500The inverter has lost communication with the lithium battery BMS over the battery communication port.
- Growatt Error 502Battery voltage is below the inverter's low battery-voltage limit.
- Growatt Error 503Battery voltage is above the inverter's high battery-voltage limit. The same condition appears as the 'Bat Voltage High' warning before it trips.
- Growatt Error 505Battery polarity is reversed at the inverter battery input.
- Growatt Error 506The inverter detects an open battery circuit (lithium battery). Warning 506 is a different code — battery temperature out of range.
- Growatt Error 507Output overload (displayed as 'Over Load'); the manual's first check is whether the load power is greater than the lithium battery's rated power.
- Growatt Error 600Output short circuit detected at the inverter output.
- Growatt Error 604EPS/backup output voltage is below specification.
- Growatt Error 607EPS/backup output overload. The same event is shown as the 'Over Load' warning, and three overloads lock the off-grid function for one hour.
- Growatt No UtilityNo grid supply is detected (warning, not a fault).
- Growatt PairingTime OutThe inverter timed out trying to pair with the SP-CT (communication fault).
- Growatt PV1 shortPV1 input is short-circuited (displayed as 'Pv1 short').
- Growatt PV2 shortPV2 input is short-circuited (displayed as 'Pv2 short').
- Growatt Warning 203PV1 or PV2 input is detected as a short circuit (Warning 203 — distinct from Error 203, which is PV isolation low).
- Growatt Warning 401SP-CT/meter communication fault — the inverter cannot read the CT or meter (shown as 'Meter Communication fault' on the BH-UP).
- Growatt Warning 506Battery temperature is outside the range allowed for charge or discharge.
Before you reset a Growatt fault
- 1Write down the exact code and any letter before it, and check which Growatt model is showing it. The same number can mean different faults on an inverter and on a battery.
- 2Isolate the AC and DC sides before touching terminals, then run the checks on the code's page in order.
- 3If the code comes straight back after a reset, stop resetting it. A repeating fault points to a real wiring, battery or hardware problem.