Error code library · 16 codes
SMS Sunmate Solar error codes
Every SMS Sunmate Solar error and fault code we have documented for Anern AN-SCI-EVO OEM series (SMS 2 kVA/12 V, 4.2 kW/24 V, 10.2 kVA/48 V hybrid units). Each code has its own guide: what it means, the likely causes, checks to run in order, fixes and when to escalate. Compiled from SMS Sunmate Solar manuals; always confirm the code on your own unit and firmware.
Anern AN-SCI-EVO OEM series (SMS 2 kVA/12 V, 4.2 kW/24 V, 10.2 kVA/48 V hybrid units)16 codes
- SMS Sunmate Solar 01Fan failure: the cooling fan is blocked or not turning. The same code appears as a warning when the fan is blocked while the inverter is running.
- SMS Sunmate Solar 02Over-temperature: internal component temperature above 100 °C, or converter temperature above 120 °C.
- SMS Sunmate Solar 03Battery over-voltage: the battery bank is charged above the inverter's high-voltage limit. The same number is also used as a warning (beep once per second) when the battery is overcharged.
- SMS Sunmate Solar 04Battery under-voltage: the bank has discharged below the inverter's low-voltage cutoff. The same number is also used as a low-battery warning (beep once per second).
- SMS Sunmate Solar 05Output short circuit: a short is detected on the AC output.
- SMS Sunmate Solar 06Abnormal output voltage: the inverter output is above 260 V AC (the manual groups 06 and 58 as output voltage outside the 190–260 V AC band).
- SMS Sunmate Solar 07Overload timeout: the inverter has been loaded above 110% of its rating and the overload timer has expired, so the output is switched off.
- SMS Sunmate Solar 08DC bus over-voltage: the internal DC bus has gone above its limit because internal components have failed.
- SMS Sunmate Solar 09Bus soft start failed: the DC bus did not come up during the soft-start sequence — an internal hardware fault.
- SMS Sunmate Solar 51Over-current or surge: the output stage has seen a current or voltage surge beyond its limit.
- SMS Sunmate Solar 52DC bus under-voltage: the internal DC bus has fallen below its minimum.
- SMS Sunmate Solar 53Inverter soft start failed: the inverter stage did not start cleanly — an internal fault, often triggered by a short or overload at switch-on.
- SMS Sunmate Solar 55Asymmetric AC output: DC voltage is present on the AC output, so the output waveform is not symmetrical.
- SMS Sunmate Solar 57Current sensor failed: the output current sensor is not reading, so the inverter cannot protect the output.
- SMS Sunmate Solar 58Abnormal output voltage: the inverter output is below 190 V AC (the manual groups 06 and 58 as output voltage outside the 190–260 V AC band).
- SMS Sunmate Solar 59PV voltage exceeds the limit: the solar input voltage is above the inverter's 500 V DC maximum.
Before you reset a SMS Sunmate Solar fault
- 1Write down the exact code and any letter before it, and check which SMS Sunmate Solar model is showing it. The same number can mean different faults on an inverter and on a battery.
- 2Isolate the AC and DC sides before touching terminals, then run the checks on the code's page in order.
- 3If the code comes straight back after a reset, stop resetting it. A repeating fault points to a real wiring, battery or hardware problem.