Error code library · 48 codes
Itel Energy error codes
Every Itel Energy error and fault code we have documented for IPV series (IPV-4K24U, IPV-6K48U, IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — warning and fault code, IPV series (IPV-4K24U, IPV-6K48U, IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter warning code, IPV Pro series (IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter warning code, IPV series (IPV-4K24U, IPV-6K48U, IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter fault code and IPV Pro series (IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter fault code. Each code has its own guide: what it means, the likely causes, checks to run in order, fixes and when to escalate. Compiled from Itel Energy manuals; always confirm the code on your own unit and firmware.
IPV series (IPV-4K24U, IPV-6K48U, IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — warning and fault code3 codes
- Itel Energy 01Display code 01 covers two events: as a warning it signals output overload (flashing fault LED, two beeps per second); as a fault it signals DC bus over-voltage (solid fault LED, output switched off).
- Itel Energy 02Display code 02 covers two events: as a warning it signals the upper cooling fan is locked (three beeps); as a fault it signals DC bus under-voltage (solid fault LED, output switched off).
- Itel Energy 03Display code 03 covers two events: as a warning it signals the lower cooling fan is locked (three beeps); as a fault it signals that the DC bus soft-start sequence failed (solid fault LED).
IPV series (IPV-4K24U, IPV-6K48U, IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter warning code2 codes
IPV Pro series (IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter warning code2 codes
IPV series (IPV-4K24U, IPV-6K48U, IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter fault code36 codes
- Itel Energy 10The inverter soft-start sequence failed because of an internal component fault, so the output was switched off.
- Itel Energy 11The inverter's software detected an over-current or surge condition and shut down the output.
- Itel Energy 12The inverter's hardware over-current protection tripped in response to an over-current or surge condition.
- Itel Energy 13Inverter output voltage has fallen below the expected level, so the unit has switched off its output.
- Itel Energy 14The inverter's output voltage rose above the permitted level, so the output was switched off.
- Itel Energy 15A short circuit has been detected on the AC output, so the inverter has shut down its output.
- Itel Energy 16The inverter's output current sensor has failed or is giving an invalid reading.
- Itel Energy 17The inverter detected current being fed back into its output, which the manual links to reversed L/N wiring or incorrect parallel sharing-cable wiring.
- Itel Energy 20The output load stayed above the inverter's overload threshold for longer than the permitted time, so the output was switched off.
- Itel Energy 21The output (OP) current sensor has failed.
- Itel Energy 22The current sensor used for load sharing between parallel units has failed.
- Itel Energy 23The AC input and AC output wiring is reversed, or the AC wiring between parallel units is incorrect.
- Itel Energy 24The output relay did not operate correctly, so the inverter cannot confirm its output connection.
- Itel Energy 30Battery bank voltage is above the inverter's high-DC limit.
- Itel Energy 31Over-current occurred in the DC/DC converter circuit.
- Itel Energy 32The DC/DC current sensor has failed.
- Itel Energy 33The No.2 DC/DC current sensor has failed.
- Itel Energy 34The DC/DC converter soft-start sequence failed.
- Itel Energy 35The hardware protection circuit detected over-current in the DC/DC circuit.
- Itel Energy 36Over-current occurred in the LLC resonant circuit.
- Itel Energy 40PV array open-circuit voltage is above the inverter's maximum PV input voltage.
- Itel Energy 41A short circuit has been detected at the PV input port.
- Itel Energy 43Over-current occurred at the PV input port.
- Itel Energy 50A cooling fan is locked, so the inverter has shut down to protect itself.
- Itel Energy 51Temperature of the internal PV-circuit components is above the permitted limit.
- Itel Energy 52Temperature of the internal inverter (INV) components is above the permitted limit.
- Itel Energy 53Temperature of the battery converter (Convert L) components is above the permitted limit.
- Itel Energy 54Temperature of the internal Convert H components is above the permitted limit.
- Itel Energy 55Temperature of the internal LLC transformer (LLC TX) is above the permitted limit.
- Itel Energy 60CAN communication between the parallel units has been lost.
- Itel Energy 61Host data between the parallel units has been lost, so the master/slave link is not working.
- Itel Energy 62Synchronisation data between the parallel units has been lost, so the units cannot synchronise their outputs.
- Itel Energy 63The parallel units are not running the same firmware version, so they cannot operate as a coordinated system.
- Itel Energy 64The output current of each parallel inverter is different, so load sharing is not working.
- Itel Energy 65The parallel units are configured with different AC output modes (single-phase PAL versus three-phase P1/P2/P3).
- Itel Energy 66A single unit is configured or connected as part of a parallel system, or the parallel wiring is incomplete.
IPV Pro series (IPV-4K24U Pro, IPV-6K48U Pro, IPV-12K48U) — inverter fault code5 codes
- Itel Energy 42The inverter detected abnormal PV input power.
- Itel Energy 44The PV current sensor has failed.
- Itel Energy 45PV1 input power is above the inverter's permitted power for that input.
- Itel Energy 46PV2 input power is above the inverter's permitted power for that input.
- Itel Energy 92The DSP failed to communicate with the MCU inside the inverter.
Before you reset a Itel Energy fault
- 1Write down the exact code and any letter before it, and check which Itel Energy model is showing it. The same number can mean different faults on an inverter and on a battery.
- 2Isolate the AC and DC sides before touching terminals, then run the checks on the code's page in order.
- 3If the code comes straight back after a reset, stop resetting it. A repeating fault points to a real wiring, battery or hardware problem.