Error code library · 60 codes
SRNE error codes
Every SRNE error and fault code we have documented for HESP series hybrid inverters (single-phase 4-12 kW and three-phase 8-12 kW), HESP three-phase hybrid (HESP H3/SH3 8-12 kW); code not listed in the single-phase HESP table and IESP 50-60 kW C&I three-phase hybrid inverter. Each code has its own guide: what it means, the likely causes, checks to run in order, fixes and when to escalate. Compiled from SRNE manuals; always confirm the code on your own unit and firmware.
HESP series hybrid inverters (single-phase 4-12 kW and three-phase 8-12 kW)50 codes
- SRNE 01Battery undervoltage alarm: the battery voltage has fallen below the [Batt. Under volt. alarm] value under Battery Setup, and the alarm does not by itself stop the output.
- SRNE 02Battery discharge average current overcurrent, detected by software (BatOverCurrSw); the inverter limits or stops discharge.
- SRNE 03Battery not connected (BatOpen): the inverter cannot see a battery on the DC side and stops the output.
- SRNE 04Battery undervoltage stop-discharge (BatLowEod): the battery has reached the low-voltage cut-off and the inverter has stopped discharging.
- SRNE 05Battery overcurrent detected by hardware protection (BatOverCurrHw); the inverter shuts the output down.
- SRNE 06Charging overvoltage protection (BatOverVolt): battery voltage rose above the over-voltage cut-off and charging was stopped.
- SRNE 07Internal DC bus overvoltage detected by hardware protection (BusOverVoltHw); the inverter stops the output.
- SRNE 08Internal DC bus overvoltage detected by software protection (BusOverVoltSw); the inverter stops the output.
- SRNE 09PV overvoltage protection (PvVoltHigh): the PV input voltage exceeded the maximum allowed and PV boosting stopped.
- SRNE 10PV boost overcurrent detected by software (PvOCSw); the inverter limits PV input and may stop PV charging.
- SRNE 11PV boost overcurrent detected by hardware protection (PvOCHw); PV charging is stopped.
- SRNE 13Bypass overload protection (OverloadBypass): the load on the bypass/AC-input path exceeded its rating for too long.
- SRNE 14Inverter overload protection (OverloadInverter): output power or current stayed above the inverter rating for the permitted time.
- SRNE 15Inverter overcurrent detected by hardware protection (AcOverCurrHw); the output is switched off.
- SRNE 17Inverter short-circuit protection (InvShort): a short was detected on the AC output, so the output was switched off.
- SRNE 19PV/buck heat-sink overtemperature protection (OverTemperMppt); PV charging is stopped until the heat sink cools.
- SRNE 20Inverter/AC-charge heat-sink overtemperature protection (OverTemperInv); output and charging stop until the unit cools.
- SRNE 21Fan failure (FanFail): the hardware detected that a cooling fan is blocked or not turning.
- SRNE 22EEPROM memory failure: the inverter cannot read or write its parameter memory.
- SRNE 23Model setting error (ModelNumErr): the configured model does not match the hardware.
- SRNE 26Relay short / AC output backfeeding to the bypass AC input (RlyShort): the AC input relay is stuck or output voltage is reaching the AC input.
- SRNE 29Low bus voltage / internal battery boost circuit failure (BusVoltLow).
- SRNE 30Battery capacity low alarm 1 (BatCapacityLow1): BMS reports SOC below the first low-capacity threshold, 10 percent in the single-phase table and 15 percent in the three-phase table.
- SRNE 31Battery capacity low alarm 2 (BatCapacityLow2): BMS reports SOC below the second, deeper low-capacity threshold (5 percent).
- SRNE 32Battery capacity low stop (BatCapacityLowStop): the inverter stops discharging because the BMS reported the battery capacity as critically low.
- SRNE 34CAN communication fault in parallel operation (CanCommFault).
- SRNE 35Parallel ID (communication address) setting error (ParaAddrErr): two units share the same parallel address.
- SRNE 37Parallel current-sharing fault (ParaShareCurrErr): the parallel units are not sharing load current evenly.
- SRNE 38Large battery voltage difference in parallel mode (ParaBattVoltDiff).
- SRNE 39Inconsistent AC input source in parallel mode (ParaAcSrcDiff).
- SRNE 40Hardware synchronisation signal error in parallel mode (ParaHwSynErr).
- SRNE 41Inverter DC voltage error / abnormal DC component in the output voltage (InvDcVoltErr).
- SRNE 42Inconsistent system firmware version in parallel mode (SysFwVersionDiff).
- SRNE 43Parallel line connection error (ParaLineContErr): the parallel communication or current-sharing wiring is incorrect.
- SRNE 44Serial number error: no serial number was set in the unit at the factory.
- SRNE 45Error setting of split-phase mode (Item "Parallel" setting error): one unit in the parallel system has the wrong parallel-mode setting.
- SRNE 49Grid over-voltage: grid voltage is above the upper limit of the selected grid standard, so the inverter disconnects from the grid.
- SRNE 50Grid under-voltage: grid voltage is below the lower limit of the selected grid standard, so the inverter disconnects from the grid.
- SRNE 51Grid over-frequency: grid frequency is above the upper limit of the selected grid standard.
- SRNE 52Grid under-frequency: grid frequency is below the lower limit of the selected grid standard.
- SRNE 53Grid loss / grid not connected: the inverter sees no valid AC input and runs from battery and PV.
- SRNE 54Grid DC current over limit: the DC component of the current exported to the grid exceeded the allowed value.
- SRNE 55Grid standard not initialised: no on-grid standard has been selected, so the inverter will not connect to the grid.
- SRNE 56Low insulation resistance fault: PV+ or PV- impedance to ground is abnormally low.
- SRNE 57Leakage current overload fault: system leakage current exceeded the limit, so the inverter disconnected.
- SRNE 58BMS communication error: the inverter cannot communicate with the lithium battery BMS.
- SRNE 60BMS battery low temperature alarm: the BMS reports the battery temperature below its low-temperature limit.
- SRNE 61BMS battery over-temperature alarm: the BMS reports the battery temperature above its high-temperature limit.
- SRNE 62BMS battery overcurrent alarm: the BMS reports battery current above its limit.
- SRNE 63BMS battery undervoltage alarm: the BMS reports battery voltage below its low-voltage limit.
HESP three-phase hybrid (HESP H3/SH3 8-12 kW); code not listed in the single-phase HESP table9 codes
- SRNE 12SPI communication fault between the master and slave control chips inside the inverter (SpiCommErr).
- SRNE 16Slave chip OFF request fault (AuxDSpReqOffPWM): an internal auxiliary controller requested the PWM stage to shut down.
- SRNE 18Bus soft-start failure (Bussoftfailed): the internal DC bus did not reach its operating voltage during soft start.
- SRNE 24Positive and negative bus voltage imbalance (Busdiff): the two halves of the internal DC bus are not balanced.
- SRNE 25Bus short circuit (BusShort): a short was detected on the internal DC bus.
- SRNE 27Grid input phase loss (LinePhaselose): one phase of the three-phase AC input is missing.
- SRNE 28Grid input phase error (LinePhaseErr / grid input phase fault): the AC input phase does not match the inverter's expected phase relationship.
- SRNE 33Control CAN fault in parallel operation (ControlCanFault).
- SRNE 36Balanced bridge arm overcurrent fault (Balance currentOC): the neutral/balance bridge arm exceeded its current limit.
IESP 50-60 kW C&I three-phase hybrid inverter1 codes
Before you reset a SRNE fault
- 1Write down the exact code and any letter before it, and check which SRNE model is showing it. The same number can mean different faults on an inverter and on a battery.
- 2Isolate the AC and DC sides before touching terminals, then run the checks on the code's page in order.
- 3If the code comes straight back after a reset, stop resetting it. A repeating fault points to a real wiring, battery or hardware problem.